標準參數(有關選配項,請聯系Grylls)
|
產品性能參數
|
Grylls8100系列科里奧利質量流量控制器
|
質量流量精度
|
Liquid:±0.2% /±0.6% of reading or ±0.05% /±0.2% of full scale,
whichever is greater
Gas:±0.5%/±1% of reading or ±0.05%±0.2% of full scale,
whichever is greater
|
重復性
|
±0.05% of reading or ±0.025% of full scale, whichever is greater
|
控制范圍
|
1%–100% /2%–100%of full scale
|
密度精度1
|
<±5 kg/m3
|
溫度精度2
|
±0.5℃
|
可測密度范圍
|
10–2,000 kg/m?
|
粘度范圍
|
0–500 cP
Consult Grylls for higher viscosity options
|
零點穩定性
|
±0.05% of full scale (included in mass flow accuracy)
|
溫度敏感性3
|
Mass flow zero shift: ±0.01% of full scale per °C from tare temperature
Mass flow span shift: ±0.005% of reading per °C from 25°C
|
閥門類型
|
Normally Closed
|
典型響應時間
|
40g/h-5kg/h<100 ms
1kg/h-600kg/h<200 ms
|
典型控制時間4
|
40g/h-5kg/h<200 ms
1kg/h-600kg/h<300 ms
|
1. 密度讀數和密度精度與質量流量讀數和質量流量精度無關.
|
2. 溫度讀數和溫度精度與質量流量讀數和質量流量精度無關.
|
3. 當質量流量為40 g/h及更小時,質量流量的零點漂移為滿量程的±0.025%每攝氏度.
|